The information above is based on generic XY-CD60 documentation. Always verify the voltage limits of your specific battery type (e.g., 12V12 cap V Lead Acid, 3.7V3.7 cap V 3.2V3.2 cap V LiFePO4) before setting parameters to avoid damage.
: Supports DC 6V to 60V, making it compatible with various lithium and lead-acid battery setups. Dual Working Modes :
Prevents over-discharge. The battery connects to the input, and the load to the output. It shuts off the load when the battery hits the Lower Limit (dn) and reconnects when the voltage rises back to the Upper Limit (UP) . Key Specifications Operating Voltage: DC 6V–60V.
This mode prevents over-discharge, which can ruin battery cells. The relay closes (connects load) when voltage is above UP .
: If you need timed cycles, you can set the OP parameter (time-limited charging/discharging). Helpful Tips xycd60 manual link
Short-press SET to cycle through parameters ( UP , dn , OP , FOP , L-P ).
The relay closes (starts charging) when the voltage drops below dn .
The relay opens (disconnects load) when voltage drops below dn . 3. XY-CD60 Setup Guide: Step-by-Step
: Emergency stop (Enable/Disable relay). Displays "OFF" when the relay is forced open. The information above is based on generic XY-CD60
(Only in discharging mode). This sets a delay buffer before the relay re-engages. Adjust using UP/DOWN, then press SET .
According to the manual, this means:
Flip your XYCD60 device over. Look for an sticker (e.g., 2A2ZR-XYCD60 ). Then:
XY-CD60 Manual Link & Comprehensive User Guide: Mastering Battery Control Dual Working Modes : Prevents over-discharge
A: Yes. The official manual link includes multi-language PDF options (Spanish, French, German, and Simplified Chinese). Look for the language flag icons next to the download button.
. It acts as a voltage-controlled switch (relay) that protects batteries from overcharging and over-discharging. 1. Key Specifications Voltage Range: DC 6V to 60V. Control Mode: Charging Mode (IN) and Discharging Mode (OUT). HD LCD showing voltage, percentage, and time. Relay Action: Only acts as a switch; it change the voltage or limit current. 2. Mode Selection To switch between Charging and Discharging modes: Long-press the button for about 5 seconds. The screen will display for Charging Mode or for Discharging Mode. 3. Parameter Settings
Long press the SET button for more than 3 seconds. The screen will display the current mode ( UP or dn ).
Short press to toggle the relay ON/OFF (emergency stop). Long press to set the LCD backlight behavior (L-P). RoboFactory 2. Setting Parameters Enter Setup: Long press Select Parameter: Short press to cycle through: : Upper limit voltage. : Lower limit voltage. : Conduction/Working time. : Delay on time (0–999 seconds). : Forced on time (Discharge mode only). Adjust Values: buttons to increase/decrease values. Save & Exit: Long press for 5 seconds. Working Logic XY-CD60 Solar Battery Charger Controller Module User Manual
Ensure proper input voltage (6-60V). The meter is designed for DC voltage measurements.
Connect your DC load (inverter, motor, lights) to the and OUT- terminals. 7. Troubleshooting Common Error Codes