Includes 2 works-adjusted alarms and a potential-free output for driving recorders or external meters. Maintenance:
involves understanding its role as a critical environmental guardian on ships. Developed by DECKMA HAMBURG GmbH , it ensures that oily water is not illegally discharged into the ocean.
Replacing electronic components (except fuses) typically requires re-calibration to avoid inaccurate readings. Troubleshooting Indicators
Mount the instrument on a vertical bulkhead near the Oily Water Separator (OWS). deckma omd11 manual
Disclaimer: This article is based on publicly available documentation for the Deckma OMD-11. Always refer to the original instruction manual provided by the manufacturer with your specific unit for the most accurate information. If you'd like, I can:
Fix : Check continuity across the relay terminals during a test alarm.
Indicates that the oil content has exceeded the setting. Includes 2 works-adjusted alarms and a potential-free output
The manual's first operational section is commissioning. Before startup, the manual instructs technicians to perform rigorous checks: verifying that the is correctly connected, ensuring proper grounding (PE) is made per regulations, and checking all piping connections for leaks. For units with an automatic cell cleaning unit, the manual specifies that the air supply must be regulated to between 4 and 6 bar. Once these checks are complete, the OMD-11 is ready for its start-up sequence.
While specific installation diagrams are detailed in the official instruction manual, the following steps provide a general overview for the OMD-11:
The OMD-11 is part of a broader family of DECKMA oil-in-water monitors, which includes newer models like the OMD-21, OMD-24, OMD-2005, and OMD-2008. The OMD-11 was developed from DECKMA's extensive experience, following earlier models like the OCD series and the OMD-7, which was the first to distinguish between oil, solids, and turbidity. It is important to note that as of this writing, the DECKMA OMD-11 is an older unit that is no longer in production. However, spare parts and support remain available. Always refer to the original instruction manual provided
• Optical glass tube is stained or scratched.• Electronic drift on the main board.
: The unit should be mounted near the oily-water separator to minimize lag time. It requires a clean water source for flushing and mm OD piping for sample connections. Maintenance : Regular cleaning of the measuring cell is critical. The instruction manual
Meets International Maritime Organization (IMO) Resolution A.393(X) requirements.
Direct the outlet discharge back to the bilge or waste tank. Install a manual bypass valve for cleaning fluids.