Opti Combi Manual English — Prosecure

Check for moving objects in the detection field (e.g., hanging signs, plants). Re-calibrate if necessary.

The safety curtain must be adjusted so that the row of infrared spots closest to the door passes directly through the plane of the moving door leaf without hitting the door itself. 6. Programming and Menu Settings

Adjust the radar lens orientation or digital settings to switch between a wide detection field (for standard double doors) and a narrow detection field (for single narrow corridors). Infrared Curtain Adjustment (Safety)

⚠️ The specific terminal assignment for the safety circuit may vary depending on the door control unit being used (e.g., ES 200, ES 400). Always consult the wiring diagrams for both the sensor and your specific door operator. prosecure opti combi manual english

Understanding the technical limits of the sensor prevents installation failures and hardware damage.

ProSecure Opti Combi Manual English: Complete Installation and Programming Guide

This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later. Check for moving objects in the detection field (e

Mount the sensor on the transom/header profile directly above the moving door leaf.

ON: Increases filtering to ignore falling snow or heavy rain droplets near the sensor face. The Auto-Learn Button

| Symptom | Possible Cause | Recommended Action | | :--- | :--- | :--- | | Door does not open. | Power supply issue, wiring fault, sensor incorrectly aligned. | Check power supply (11.5-32V DC). Verify wiring connections against the operator's manual. Re-align the sensor using the LCD display. | | Door opens for cross traffic. | Sensor detecting movement outside the intended zone. | Adjust the radar detection zone using the remote control or DIP switches (if equipped) and enable cross-traffic suppression. | | Door does not close or reopens unexpectedly. | The active IR curtain is detecting a false presence (e.g., a stationary object, reflections). | Re-align the IR curtain. Check for reflective surfaces (glass, metal) near the door opening. | | Sensor does not respond to command. | Electrical fault, sensor not receiving test impulse from operator. | Check the red test input wire connection. Ensure the door operator is sending a test pulse as required. | Always consult the wiring diagrams for both the

ProSecure Opti Motion Sensor Detailed Specifications (Scribd) — Covers antenna characteristics and programming options. or a specific troubleshooting code for this sensor? Prosecure Opti Motion Stereo - Ahlsell

Do not attempt to force the bolt or drill the lock before consulting the official manual. The Opti Combi contains anti-tamper mechanisms that will permanently seal the unit if tampering is detected.

Leave a Reply

Your email address will not be published. Required fields are marked *