6 Slide Scanner Optimus with IHC slide scan
Mid sized scanner with high ROI

Virbox Protector Unpack -

Scanner Specifications
Slide Rack
6 slides batched at once
with walkaway experience
Slide Types
- Slides with / without  / non-dried coverslips
- Slide thickness from 0.8 to 2mm
- Slide shapes 1”x3”  & 2”x3”
Time for 15x15mm
- 90 secs with flash mode with 3 focus points
- 150 to 250 secs with dense focus map & AI repair
- 7.5 mins with 7 Z-Stacks 1 um apart
- 15 secs fast preview with live mode
Optics & Camera
- 0.22 microns / pixel @ 40x with primary camera
- Secondary Preview Camera for macro imaging
-  High power flash LED with custom condenser
Barcode Support
All types supported including
- Linear type, example: CODE 39, CODE 128
- Matrix, example : QR code, PDF417
LIMS Integration
Custom development for bi-directional integration is included as part of installation
Data Size
450 MBs in lossless archive mode and 850 MBs within hot storage for a WSI of 15x15mm.
For Z-stack data size, it gets multiplied by a factor of the number of stacks
Image Storage
2000-3000 scans are stored in a primary hard disk and auto-rolled out to Local / Cloud archival based on retention time for hot storage.
Local: RAID 6 NAS-based chained storage
Cloud: Cold storage on Amazon Web Services @ 10 cents per slide per year
Intended Use for
1. HE & IHC stained tissue sections
2. Pap smears
3. FNAC cytology smears
Scanner Size
W x D x H (inches)
16 x 18 x 14
Weight
26 Kg (57 lb)

zoom  0.1x to 80x

Get Access to Full Scan Library
Morphle values your privacy. To learn more, read our Privacy Policy.
Thank you! Our team will get in touch within the next 60 minutes.
Oops! Something went wrong while submitting the form. Please try again.
Dr. Ingerlisa Mattoch
TIAGA Pathology, CO
virbox protector unpack
❛❛
I review approximately 120-150 slides per day (99% Dermpath). The digital slides are of a SUPERIOR RESOLUTION and the scanning time is also short. Primary punch and shave biopsies, are scanned in ~1 minute each. Excision sections (larger tissue) scan at about 2 minutes per slide. On average, we can scan 6 sets of slides in 8-10 minutes. I have worked on a number of Digital Pathology platforms, the MorphoLens scans are by far the best I have worked with from a resolution and quality perspective.
❛❛
Dr. Ingerlisa Mattoch
TIAGA Pathology, CO
virbox protector unpack

Scanning Modes

Live Microscopy Mode for Rapid on-site evaluation
#1 - Live Microscopy mode with continuous Z-stack
Uses dual objective switching system where
virbox protector unpack
4X objective does an initial whole slide scan and serves as a navigation map
virbox protector unpack
40X objective is used to fetch real-time images as the remote user navigates across 4X preview scan
Offers 2 focusing modes
virbox protector unpack
Continuous Focus for Tissue section slides (recommended for Frozen Section remote reporting)
virbox protector unpack
Continuous Z-stack for Cytology smear slides (recommended for any slide with overlapping cells)
Live microscopy is preferred over other modes where one needs the ability to start the diagnosis immediately after slide preparation
Whole Slide Imaging WSI with AI enabled tools
#2 - Whole Slide Imaging (WSI)

The classical scanning mode where the variation of a focal plane if any is pre-calculated with a focus map and later the motorized XY stage captures optimally focused images by translating across the region of the scanning.

Uses single 40X or 20X objective combined with a secondary overhead camera for capturing preview (thumbnail) of the full slide including the barcode area.

Whole slide imaging is preferred over other modes when exhaustive image capture is needed for deferred access.

Volume Scanning Mode for telecytology
#3 - Volume Scanning

An all powerful scanning mode where multiple images covering all focal planes are captured at every field. The end result is essentially a whole slide scan mixed with pre-captured Z-stack at every position.

Similar to WSI mode, Volume scanning uses a single 40X or 20X objective combined with a secondary overhead camera for capturing preview (thumbnail) of the full slide including the barcode area.

Volume scanning is preferred over WSI when exhaustive image capture is needed for slides with overlapping cells such as Fine Needle Aspiration Biopsy slides, Pap smear slides etc.

Tiny yet Mighty details
virbox protector unpack
Live Mode for
ROSE & Frozen
Start Reporting 40X remotely in 15 seconds. Report instantly for frozen section, cytology adequacy, FNA.
virbox protector unpack
Ultra-fast
Z-stacking
Move across multiple Z-levels at each field. Scan Cytology slides with overlapping cells.
virbox protector unpack
Digital Cytology
Reporting
Compare shortlisted cells side by side. Track area screened to ensure coverage.
virbox protector unpack
Bi Directional
LIS Integration
Access Patient data and TRF forms embedded into the digital pathology viewer. Push microscopic photographs, gross images to final report.
virbox protector unpack
IHC Cell Counting
Automated positive and negative cell counting with positivity ratio. 3rd party application that is approved for research use for nuclear and membrane staining antibodies.
virbox protector unpack
Hassle free scoring
& measurements
Measure tumor margins and more in full tissue view. Measure nuclear diameters, area and more at micrometer accuracy.
virbox protector unpack
Scan Sync
Compare HE and multiple IHC scans side by side. Eliminates hassle of marking on/switching glass slides in microscope compounding factors.
virbox protector unpack
Hi DPI Publication ready image export
Full tissue image capture for large tissue that don't fit in a single field at even a 2X microscope objective. One click export with perfect image quality
5 Million+ slides reported on Morphle whole slide scanners and counting!
virbox protector unpack
Join the Digital Pathology revolution!
Shipping across the Globe.

Virbox Protector Unpack -

Researchers often use hardware breakpoints on execution or monitor system calls like VirtualProtect to see when the original code sections are being marked as executable. 2. Dumping the Memory

Irrelevant instructions that consume CPU cycles but do not change the program state.

Virbox Protector is a software protection solution developed by Virbox, designed to protect software applications from unauthorized access, modification, and reverse engineering. It uses advanced encryption and anti-debugging techniques to safeguard software against various types of attacks. Virbox Protector supports multiple programming languages, including C++, Java, and .NET.

Follow that pointer in the dump to see where it leads. If it leads to a Virbox heap stub, trace the stub execution until it resolves the final API destination (e.g., Kernel32.dll!VirtualAlloc ).

Before writing any code or running a debugger, start with information gathering. Use tools like Detect It Easy (DIE) or Exeinfo PE to identify the specific packer and its version. It's crucial to perform this analysis in a safe, isolated virtual machine to prevent any damage to your host system. Remember to disable any antivirus software temporarily, as it may interfere with your work. virbox protector unpack

Debugger artifacts via API calls like IsDebuggerPresent() and CheckRemoteDebuggerPresent() .

Analysts often use memory breakpoints on the .text section of the primary module.

Continuously monitors Thread Local Storage (TLS) and thread contexts to clear or detect hardware breakpoints ( DR0 – DR3 ).

Set a memory breakpoint (Hardware On Access or Memory Execution) on the .text section of the primary module. Press to run the application. Researchers often use hardware breakpoints on execution or

It hides the Import Address Table (IAT) and dynamically resolves Windows APIs at runtime to defeat static analysis.

Once all imports are valid, click and select your previously saved dumped.exe . This generates a fully functional executable (e.g., dumped_SCY.exe ). 4. Confronting the Virtualization Layer

To unpack Virbox Protector, you must first understand the defensive layers it applies to an executable:

We set a memory breakpoint on the original Notepad’s string resource ("Untitled - Notepad"). After 3 million instructions, execution lands in a decrypted block containing the WinMain function. Virbox Protector is a software protection solution developed

Process Monitor (Sysinternals) and API Monitor. Configuring ScyllaHide Open x64dbg and navigate to the ScyllaHide options.

Utilizing RDTSC (Read Time-Stamp Counter) to detect execution delays caused by single-stepping.

Fragmenting code to destroy function boundaries, making static analysis nearly impossible.

Finding the OEP and fixing the IAT works for basic protection levels. However, if the developer enabled on critical functions, those functions are compiled into randomized bytecode. Unpacking a virtualized binary requires "devirtualization":